High-throughput virus quantification using cytopathic effect area analysis

Adaptation of these methods to high-throughput formats (96-, 384- or 1,536-well plates) is challenging due to both assay automation constraints and the lack of well surface area available for reliable analysis. Here, we present a scalable alternative to traditional methods that uses whole-well image thresholding to quantify infectious virions by measuring virus-induced cytopathic effect (CPE) via cell lysis and detachment.

High-throughput virus quantification using cytopathic effect area analysis

Share this story

Send the public story page.

Useful takeaways from this story.

Adaptation of these methods to high-throughput formats (96-, 384- or 1,536-well plates) is challenging due to both assay automation constraints and the lack of well surface area available for reliable analysis.

To improve analysis efficiency and reduce user bias in CPE area selection, we evaluated an nnU-Net model for automated image segmentation against images segmented by manually defined brightness thresholds.

Here, we present a scalable alternative to traditional methods that uses whole-well image thresholding to quantify infectious virions by measuring virus-induced cytopathic effect (CPE) via cell lysis and...

Building the complete brief

The page is ready to read now. The fuller skim-friendly version will appear here automatically.

The useful part

Adaptation of these methods to high-throughput formats (96-, 384- or 1,536-well plates) is challenging due to both assay automation constraints and the lack of well surface area available for reliable analysis. Here, we present a scalable alternative to traditional methods that uses whole-well image thresholding to quantify infectious virions by measuring virus-induced cytopathic effect (CPE) via cell lysis and detachment. The CPE area assay is best positioned as a practical high-throughput preliminary screening tool, effectively quantifying samples within the assay range and flagging samples above or below the concentration thresholds.

How it works

  • To improve analysis efficiency and reduce user bias in CPE area selection, we evaluated an nnU-Net model for automated image segmentation against images segmented by manually defined brightness thresholds.
  • The model achieved strong correlation with manual thresholding (R 2 = 1.00), showing minimal differences in the identified CPE area and thus demonstrating that nnU-Net accurately reproduces manual analysis.
  • Paul Morris Traditional infectivity-based virion quantification methods, such as 50% tissue culture infectious dose (TCID 50) and plaque assays, are typically performed in 6-, 12-, 24-, or 48-well cell...
  • This approach provides two complementary pipelines: manual thresholding, which tolerates adjustments of hyperparameters, and fully automated segmentation via nnU-Net, which streamlines analysis and enhances...
  • This flexible CPE area assay enables accurate and automated quantification in high-throughput screening formats, thereby greatly accelerating a routine laboratory task while decreasing subjectivity and bias.